checkCIF/PLATON report (publication check)

No syntax errors found.                               CIF dictionary
Please wait while processing .... Interpreting this report
Datablock: shelxl
Bond precision: O- C = 0.0400 A Wavelength=0.71073
Cell: a=10.356(5) b=12.199(9) c=19.104(14)
alpha=88.72(2) beta=86.41(2) gamma=69.02(2)
Calculated Reported
Volume 2249(3) 2249(3)
Space group P -1 P -1
Hall group -P 1 ?
Moiety formula C38 H48 Fe2 O2 S6 Si4 ?
Sum formula C38 H48 Fe2 O2 S6 Si4 C19 H24 FE O S3 SI2
Mr 953.24 476.59
Dx,g cm-3 1.408 1.408
Z 2 4
Mu (mm-1) 1.062 1.062
F000 992.0 992.0
F000' 995.72
h,k,lmax 10,12,19 10,12,19
Nref 5001 4370
Tmin,Tmax 0.805,0.928 0.770,0.929
Tmin' 0.759
Correction method= 'MULTI-SCAN'
Data completeness= Ratio = 0.874 Theta(max)= 21.240
R(reflections)= 0.1907( 1818) wR2(reflections)= 0.4858( 4370)
S = 1.024 Npar= 433

The following ALERTS were generated. Each ALERT has the format
       test-name_ALERT_alert-type_alert-level.
Click on the hyperlinks for more details of the test.

Alert level A RFACR01_ALERT_3_A The value of the weighted R factor is > 0.45 Weighted R factor given 0.486 THETM01_ALERT_3_A The value of sine(theta_max)/wavelength is less than 0.550 Calculated sin(theta_max)/wavelength = 0.5097 PLAT023_ALERT_3_A Resolution (too) Low [sin(th)/Lambda < 0.6]..... 21.24 Deg. PLAT027_ALERT_3_A _diffrn_reflns_theta_full (too) Low ............ 21.24 Deg. PLAT029_ALERT_3_A _diffrn_measured_fraction_theta_full Low ....... 0.87 PLAT084_ALERT_2_A High R2 Value .................................. 0.49
Alert level B REFLT03_ALERT_3_B Reflection count < 90% complete (theta max?) From the CIF: _diffrn_reflns_theta_max 21.24 From the CIF: _diffrn_reflns_theta_full 21.24 From the CIF: _reflns_number_total 4370 TEST2: Reflns within _diffrn_reflns_theta_max Count of symmetry unique reflns 5001 Completeness (_total/calc) 87.38% RFACG01_ALERT_3_B The value of the R factor is > 0.15 R factor given 0.191 RINTA01_ALERT_3_B The value of Rint is greater than 0.15 Rint given 0.191 PLAT020_ALERT_3_B The value of Rint is greater than 0.10 ......... 0.19 PLAT022_ALERT_3_B Ratio Unique / Expected Reflections too Low .... 0.87 PLAT082_ALERT_2_B High R1 Value .................................. 0.19 PLAT241_ALERT_2_B Check High Ueq as Compared to Neighbors for C23 PLAT241_ALERT_2_B Check High Ueq as Compared to Neighbors for C25 PLAT242_ALERT_2_B Check Low Ueq as Compared to Neighbors for C24 PLAT412_ALERT_2_B Short Intra XH3 .. XHn H23 .. H35A .. 1.74 Ang.
Alert level C PLAT026_ALERT_3_C Ratio Observed / Unique Reflections too Low .... 42 Perc. PLAT041_ALERT_1_C Calc. and Rep. SumFormula Strings Differ .... ? PLAT045_ALERT_1_C Calculated and Reported Z Differ by ............ 0.50 Ratio PLAT048_ALERT_1_C MoietyFormula Not Given ........................ ? PLAT125_ALERT_4_C No _symmetry_space_group_name_Hall Given ....... ? PLAT241_ALERT_2_C Check High Ueq as Compared to Neighbors for C7 PLAT241_ALERT_2_C Check High Ueq as Compared to Neighbors for C12 PLAT241_ALERT_2_C Check High Ueq as Compared to Neighbors for C31 PLAT242_ALERT_2_C Check Low Ueq as Compared to Neighbors for Si1 PLAT242_ALERT_2_C Check Low Ueq as Compared to Neighbors for C13 PLAT242_ALERT_2_C Check Low Ueq as Compared to Neighbors for C22 PLAT242_ALERT_2_C Check Low Ueq as Compared to Neighbors for C26 PLAT242_ALERT_2_C Check Low Ueq as Compared to Neighbors for C32
6 ALERT level A = In general: serious problem 10 ALERT level B = Potentially serious problem 13 ALERT level C = Check and explain 0 ALERT level G = General alerts; check 3 ALERT type 1 CIF construction/syntax error, inconsistent or missing data 14 ALERT type 2 Indicator that the structure model may be wrong or deficient 11 ALERT type 3 Indicator that the structure quality may be low 1 ALERT type 4 Improvement, methodology, query or suggestion 0 ALERT type 5 Informative message, check

checkCIF publication errors

Alert level A PUBL004_ALERT_1_A The contact author's name and address are missing, _publ_contact_author_name and _publ_contact_author_address. PUBL005_ALERT_1_A _publ_contact_author_email, _publ_contact_author_fax and _publ_contact_author_phone are all missing. At least one of these should be present. PUBL006_ALERT_1_A _publ_requested_journal is missing e.g. 'Acta Crystallographica Section C' PUBL008_ALERT_1_A _publ_section_title is missing. Title of paper. PUBL009_ALERT_1_A _publ_author_name is missing. List of author(s) name(s). PUBL010_ALERT_1_A _publ_author_address is missing. Author(s) address(es). PUBL012_ALERT_1_A _publ_section_abstract is missing. Abstract of paper in English.
Alert level G PUBL013_ALERT_1_G The _publ_section_comment (discussion of study) is missing. This is required for a full paper submission (but is optional for an electronic paper). PUBL017_ALERT_1_G The _publ_section_references section is missing or empty.
7 ALERT level A = Data missing that is essential or data in wrong format 2 ALERT level G = General alerts. Data that may be required is missing

Publication of your CIF

You should always attempt to resolve as many as possible of the alerts in all categories. Often the minor alerts point to easily fixed oversights, errors and omissions in your CIF or refinement strategy, so attention to these fine details can be worthwhile. In order to resolve some of the more serious problems it may be necessary to carry out additional measurements or structure refinements. However, the nature of your study may justify the reported deviations from the submission requirements of the journal and these should be commented upon in the discussion or experimental section of a paper - after all, they might represent an interesting feature.

If level A alerts remain, which you believe to be justified deviations, and you intend to submit this CIF for publication in Acta Crystallographica Section C or Section E, you should additionally insert an explanation in your CIF using the Validation Reply Form (VRF) below. Your explanation will be considered as part of the review process.

If you intend to submit to another section of Acta Crystallographica or Journal of Applied Crystallography or Journal of Synchrotron Radiation, you should make sure that at least a basic structural check is run on the final version of your CIF prior to submission.

# start Validation Reply Form
_vrf_PUBL004_GLOBAL
;
PROBLEM: The contact author's name and address are missing,
RESPONSE: ...
;
_vrf_PUBL005_GLOBAL
;
PROBLEM: _publ_contact_author_email, _publ_contact_author_fax and
RESPONSE: ...
;
_vrf_PUBL006_GLOBAL
;
PROBLEM: _publ_requested_journal is missing
RESPONSE: ...
;
_vrf_PUBL008_GLOBAL
;
PROBLEM: _publ_section_title is missing. Title of paper.
RESPONSE: ...
;
_vrf_PUBL009_GLOBAL
;
PROBLEM: _publ_author_name is missing. List of author(s) name(s).
RESPONSE: ...
;
_vrf_PUBL010_GLOBAL
;
PROBLEM: _publ_author_address is missing. Author(s) address(es).
RESPONSE: ...
;
_vrf_PUBL012_GLOBAL
;
PROBLEM: _publ_section_abstract is missing.
RESPONSE: ...
;
_vrf_RFACR01_shelxl
;
PROBLEM: The value of the weighted R factor is > 0.45
RESPONSE: ...
;
_vrf_THETM01_shelxl
;
PROBLEM: The value of sine(theta_max)/wavelength is less than 0.550
RESPONSE: ...
;
_vrf_PLAT023_shelxl
;
PROBLEM: Resolution (too) Low [sin(th)/Lambda < 0.6].....      21.24 Deg. 
RESPONSE: ...
;
_vrf_PLAT027_shelxl
;
PROBLEM: _diffrn_reflns_theta_full (too) Low ............      21.24 Deg. 
RESPONSE: ...
;
_vrf_PLAT029_shelxl
;
PROBLEM: _diffrn_measured_fraction_theta_full Low .......       0.87      
RESPONSE: ...
;
_vrf_PLAT084_shelxl
;
PROBLEM: High R2 Value ..................................       0.49      
RESPONSE: ...
;
# end Validation Reply Form
If you wish to submit your CIF for publication in Acta Crystallographica Section C or E, you should upload your CIF via the web. If your CIF is to form part of a submission to another IUCr journal, you will be asked, either during electronic submission or by the Co-editor handling your paper, to upload your CIF via our web site.

PLATON version of 09/07/2006; check.def file version of 27/06/2006
Datablock shelxl - ellipsoid plot

Download CIF editor (enCIFer) from the CCDC
Test a new CIF entry